Thermocouple Cables

Thermocouple Cable

  • Thermocouple cable available in Armoured and Non Armoured types.
  • Not Armoured cable constructed with XLPE/IS/OS/LSZH insulation material.
  • Armoured cable constructed with XLPE/IS/OS/LSZH/SWA/LSZH insulation material and a layer of galvanized steel wire armor for added protection.
  • XLPE insulation offers excellent resistance to heat, chemicals, and electrical interference.
  • LSZH sheathing minimizes the release of smoke and toxic gases in the event of a fire, improving safety for personnel and equipment.
Operating Temperature

-20 °C to +80 °C (for general use); -40 °C to +90 °C (on request)

Not armoured type:
12 times the outer diameter
10 times the outer diameter (for conductors class 5)
Armoured type:
15 times the outer diameter

EN 50288-7 Basic design
IEC 60332-1 Flame retardant
IEC 60332-3 Fire retardant (cat. C or A according to requirements)
IEC 60754-1 Halogen free properties (only for LSZH cables)
IEC 61034-2 Low smoke emission (only for LSZH cables)

Conductors

Solid alloy

Calibration

ANSI MC 96.1 or IEC 60584-3

Insulation PVC, PE, XLPE or LSZH thermoplastic material

Twisting

The insulated cores shall be twisted in pairs for a good reduction of the electromagnetic noise.

Individual Screen

Aluminium/polyester tape, coverage >100%,
aluminium in contact with tinned copper drain wire.

Cabling

The screened pairs are cabled with suitable non hygroscopic fillers (when necessary) and wrapped with polyester tape if required.

Overall Screen

Aluminium/polyester tape, coverage >100%, aluminium in contact with tinned copper drain wire.

Inner Sheath

PE, PVC or LSZH thermoplastic material

Armour 

Single layer of galvanized steel wires (SWA)

Outer Sheath

PVC or LSZH thermoplastic material

Applications

➜ Thermocouple cable is used to measure temperature in various industrial processes


➜ Widely used in chemical processing plants, food processing facilities, pharmaceutical manufacturing plants, refineries, and oil and gas plants


➜ Helps optimize production, improve efficiency, and prevent equipment failures


➜ Used in power generation to monitor temperature in boilers, turbines, and other equipment


➜ Used in HVAC systems to monitor temperature in air handlers, chillers, and other equipment


➜ Ideal for applications where accurate temperature measurement is critical for safety and process control


➜ Available in armoured and non-armoured options to provide additional protection in harsh environments


➜ Compatible with cable tray and conduit installations for ease of use and flexibility.